NOTICE
Do not add the electrolyte to the battery exceeding UPPER LEVEL line. If the electrolyte level is too
high, it may leak and cause damage to the paint surface or corrode other parts.
When adding the purified water (such as a commercial battery fluid) in cold weather, add it before start-
ing operations in the morning to prevent the purified water from freezing.
Do not use the replenishment water for a battery which contains sulfuric acid. Density of sulfuric acid
increases and it shortens the battery life.
Inspect the battery electrolyte level at least once a month.
Open the cover (1) on the left front side of the machine. The
battery is installed at (A) part.
METHOD FOR CHECKING ELECTROLYTE LEVEL FROM SIDE OF BATTERY
If it is possible to check the electrolyte level from the side of the battery, check as follows.
1.
Use a cloth wet with water to clean the area around the
electrolyte level lines and check that the electrolyte level is
between UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.)
lines.
2.
If the electrolyte level is below the middle between UPPER
LEVEL (U.L.) and LOWER LEVEL (L.L.) lines, immediately
remove the cap (2) and add the purified water (such as a
commercial battery fluid) to U.L. line.
3.
After adding the purified water, tighten the cap (2) securely.
REMARK
If the purified water is added to above UPPER LEVEL (U.L.) line, remove the fluid by using a syringe to lower
the level to UPPER LEVEL (U.L.) line. Neutralize the removed electrolyte with baking soda (sodium bicarbon-
ate), then flush it away with a large amount of water. If necessary, consult your Komatsu distributor or a battery
manufacturer.
METHOD FOR CHECKING ELECTROLYTE LEVEL WHEN IT IS IMPOSSIBLE TO
CHECK FROM SIDE OF BATTERY
If it is impossible to check the electrolyte level from the side of the battery, or there is no UPPER LEVEL line on
the side of the battery, check as follows.
MAINTENANCE
MAINTENANCE PROCEDURE
4-49
Summary of Contents for D375A-8
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 13: ...Scale interval of the circles is 1 m FOREWORD INTRODUCTION 1 11...
Page 310: ......
Page 394: ......
Page 395: ...SPECIFICATIONS 5 1...
Page 448: ......
Page 449: ...REPLACEMENT PARTS 7 1...
Page 465: ......