![Komatsu D375A-8 Operation & Maintenance Manual Download Page 215](http://html1.mh-extra.com/html/komatsu/d375a-8/d375a-8_operation-and-maintenance-manual_1991126215.webp)
4.
Turn the starting switch key (2) to ON position (B).
5.
Check if the preheating pilot lamp on the monitor panel (3)
is lit.
If a password has been set, the input display screen will be
indicated on the monitor screen, but the preheating pilot
lamp operates in the same way as on the standard screen.
6.
Leave this condition until the preheating pilot lamp goes
out.
7.
After the preheating pilot lamp goes out, turn the key of the
starting switch (2) to START position (C), and start the en-
gine.
The lighting time of the preheating pilot lamp varies with
the ambient temperature as shown in the table.
Coolant temperature
Lighting time (sec.)
–5 to –20 °C
20 to 40
–20 to –30 °C
40
8.
When the engine starts, release the key of the starting
switch (2).
The key will return automatically to ON position (B).
REMARK
Just after starting the engine, run it at idle. During this peri-
od, release the decelerator pedal and perform no opera-
tion of the work equipment.
Standard idling time
• In cold weather: Min. 15 sec.
• First start after replacement of engine oil or engine oil
filter: 20 sec.
OPERATION
MACHINE OPERATIONS AND CONTROLS
3-157
Summary of Contents for D375A-8
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 13: ...Scale interval of the circles is 1 m FOREWORD INTRODUCTION 1 11...
Page 310: ......
Page 394: ......
Page 395: ...SPECIFICATIONS 5 1...
Page 448: ......
Page 449: ...REPLACEMENT PARTS 7 1...
Page 465: ......