3.
Check the oil level with the sight gauge (G) after approxi-
mately 5 minutes.
If the oil level is between H and L of the sight gauge (G), it
is proper.
4.
If the level is below L level, add oil through the oil filler port
(F).
NOTICE
Do not add it above H level. This will cause the oil to spurt
out
If oil has been added to above H level, stop the engine and
wait for the hydraulic oil to cool down. Then remove the
drain plug (P) and loosen the drain valve (1) to drain the
excessive oil.