9.11 Optional Connector (X6)
9.11.1 Pinout AKD-Nzzz07-DF/DG
The additional connector X6 with AKD-N-DF/DG device variants allows connection to field-
bus slave devices that are controlled by the system master.
Wiring diagram tertiary fieldbus
M12, D-coded
X6
Description
1
Tr
2
3
Transmit -
4
Receive-
9.11.2 Pinout AKD-Nzzz07-DS/DT
An additional digital input (STO-Enable) releases the power output stage of the drive as long
as a 24 V signal is applied to this input. The local STO-Enable input is galvanically isolated
and need external 24 VDC supply (PELV/SELF).
For detailled description of STO interface and functionality refer to (
Wiring diagram local STO-Enable
M12, A-coded
X6
Description
1
STO-
2
STO-Enable -
3
n.c.
4
n.c.
AKD-N Installation | 9 Electrical Installation