AKD-N Installation | 7 Technical description and data
7.7 Connectors
Given voltage and current data are the lowest values allowed by UL and CE.
Connector
Type
Max. Cross Section
Current
Voltage*
Hybrid IN, X1
Hybrid Connector
(male), 7 poles
4 x 0.34mm², 22 awg
3 x 2.5 mm², 14 awg
0.5 A
18 A
30 V
850 V
Hybrid OUT, X2
Hybrid Connector
(female), 7 poles
4 x 0.34mm², 22 awg
3 x 2.5 mm², 14 awg
0.5 A
18 A
30 V
850 V
Digital I/O, X3
Connector (female),
8 poles
8 x 0.34 mm², 22 awg
2 A
30 V
Motor/Hybrid, X4
Connector (female),
8 poles
4 x 2.5 mm², 14 awg
4 x 1.0 mm², 18 awg
15 A
10 A
630 V
30 V
Feedback X5
Connector (male),
17 poles
17 x 0.75 mm², 20 awg
3.6 A
63 V
STO/Fieldbus, X6 Connector (female),
4 poles
4 x 0.34 mm², 22 awg
1 A
50 V
* Rated voltage with pollution level 2, use Kollmorgen cables only.
30