29
5.6 EYEPIECE ADJUSTMENT AND COLLIMATING OBJECT
Method of Collimating Object
(
for reference
)
①
Sight the Telescope to bright place and rotate the eyepiece tube to make the
reticle clear.
②
Collimate the target point with top of the triangle mark in the coarse
collimator. (Keep a certain distance between eye and the coarse collimator).
Make the target image clear with the telescope focusing screw.
☆
if there is parallax when your eye moves up, down or left, right, it means the diopter of
eyepiece lens or focus is not well adjusted and accuracy will be influenced, so you should adjust
the eyepiece tube carefully to eliminate the parallax.
5.7 VERTICAL AND HORIZONTAL ANGLE TILT CORRECTION
When the tilt sensors are activated, there will be an automatic compensation value
added into the vertical and horizontal angles.
Tilt sensor must be turned on; it can help improve the precision. When a dialog of
compensation displays, it indicates that the instrument is out of automatic
compensation range (±3.5′), and must be leveled manually.
KTS-470(R) Series compensates the inclination in both X and Y directions.
Example
:
OPERATION STEPS
KEY
DISPLAY
If the instrument hasn‟t been
leveling, a compensation dialog box
will pop up automatically. As
shown in the right graph.