6.2.4 Setting the Prism Constant
Since the constants of prisms manufactured by different companies are different, the
corresponding prism constant must be set. Once the prism constant is set, it would be
kept even if the machine is turned off.
OPERATION STEPS
OPERATION
DISPLAY
①
In the menu of total station,
click “Meas.Setup” and
then click “Atmospheric
Parameters”
“Meas.Setup”
+
“Atmospheric
Parameters”
②
Current
Atmospheric
Parameters display on the screen.
Use stylus to move cursor to
PSM input area, delete data and
input new numbers.
※
1)
Input Value
③
Click [Save].
[Save]
④
Click [OK] to save.
[OK]
※
1) The scope of prism constant
:
-100mm
~
+100mm, Step Length 0.1mm
You also can set Prism Constant in star key (
★
)model.
6.2.5 Distance Measurement (Continuous Measurement)
Make sure the mode is Angle measurement.
See the Example in next page.