08
Table 3: Operation of the device when pumping from the water supply network (inlet pressure = 5 bar) at
different positions of the flow adjustment button using the supplied universal nozzle and the supplied fully
charged battery.
Position of the flow adjustment button
Min
25%
Medium
75%
Max
Achieved fluid pressure [bar]
6.10
9.90
13.80
18.00
23.60
Achieved fluid flow [l/min]
1.72
2.18
2.56
2.94
3.34
Achieved fluid flow [l/h]
103.20
130.80
153.60
176.40
200.40
Operating time [h]
305
125
63
34
19
The tests were performed with water at room temperature of the medium and the environment (22 ° C)
WARNING!
Maximum time of operation in a dry state (without the flow of medium
through the devices): 1 min (failure to do so may result in damage).
MAX HOSE LENGHT
from the source of the medium to the device is 30 meters. This
length is also conditioned by the time until injection or dry operating time (the permitted
dry operating time of the device is 1 minute).
DEVICE WEIGHT
incl. basic nozzle: 0.85 kg (without battery) // 1.35 kg (with battery).