Section 9 Generator Disassembly/Reassembly
13. Disconnect the FP and FN leads.
14. Remove the four bolts to remove the exciter field.
See Figure 9-5.
558864
1
2
1. Bolts (4)
2. Exciter field
Figure 9-5
Exciter Field Removal
15. Remove the three bolts and spacers from the
rectifier board.
16. Disconnect the main field rotor leads from the
rectifier
board
positive/negative
terminals.
Remove the armature retaining bolt and washer.
See Figure 9-6.
17. Remove the armature from the shaft, guiding the
rotor leads through the armature bores.
See
Figure 9-6.
558865
1
2
3
4
1. Armature
2. Armature retaining bolt
3. Rotor leads
4. Rectifier board
Figure 9-6
Armature Removal
18. Attach a hoist hook to the generator lifting eye. See
Figure 9-7.
Note:
The hoist capacity rating should be one-half
ton or greater.
19. Remove the two vibromount bolts. See Figure 9-7.
20. Raise the alternator end and place a wood block
under the locator plate. Lower the alternator until
the wood block supports the backplate.
See
Figure 9-7.
21. Remove the four overbolts from the end bracket.
558866
1
3
2
4
1. Lifting eye
2. Backplate
3. Wood block
4. Vibromounts
Figure 9-7
Supporting the Generator, Typical
Summary of Contents for 6.5-27EFOZD
Page 1: ...Marine Generator Sets Models 8 32EOZD 6 5 27EFOZD TP 6255 7 06a Service ...
Page 12: ...TP 6255 7 06 12 Service Assistance Notes ...
Page 22: ...TP 6255 7 06 22 Section 1 Specifications Notes ...
Page 28: ...TP 6255 7 06 28 Section 3 Intake and Exhaust System Notes ...
Page 62: ...TP 6255 7 06 62 Section 7 Controller Notes ...
Page 78: ...TP 6255 7 06 78 Section 8 Component Testing and Adjustment Notes ...
Page 92: ...TP 6255 7 06 92 Section 10 Wiring Diagrams Notes ...
Page 100: ...TP 6255 7 06 100 ...
Page 101: ...TP 6255 7 06 101 ...
Page 102: ...TP 6255 7 06 102 ...
Page 103: ...TP 6255 7 06 103 ...