MDC-7000/7900 Series
Chapter 2 Radar Basic Operation
0093169010-10
2-5
2.5
Change range scale
The coverage area can be changed by changing range scale.
Larger the value of range the more coverage area expands. (The target image will become smaller.)
The range scale value and range rings value are indicated at the upper left on the display.
Range scale can be changed directly at the upper left of the display, with trackball and ENT key, without
using RANGE+ and RANGE- key.
Range is changed centering on the antenna position.
1
Press Range + key to zoom out the picture, and to observe a wider area.
Press Range - key to zoom in the picture, to magnify and to observe closer to Antenna position.
Model-specific ranges are as shown below.
Model name MDC-7020/7920 (Max. output : 25 kW)
MDC-7010/7910 (Max. output : 12 kW)
MDC-7060/7960 (Max. output: 6 kW)
Range(NM)
0.125
0.25
0.5
0.75
1.5
3
6
12
24
32*
48
64*
96**
* 32NM and 64NM is for 6kW / 12kW only.
** 96NM is for 25kW only.
Change range unit (NM / km / sm / kf / ky)
The unit of range measurement can use five kinds of distance units.
Selection unit: NM: nautical mile
km: kilo meter
sm: statute mile
kf: kilo feet
ky: kilo yard
1
Press MENU key to display
“Menu”.
Select [DISPLAY] => [RANGE UNIT] => select [NM], [km], [sm], [kf] or [ky], and press ENT key.
When changing to other range unit, Range and Cursor range unit will be changed.
1.5
Indicated distance
*Bearing scale
Range
ANT position
Trackball operation
Cursor point