![Koden MDC-7010 Operation Manual Download Page 191](http://html.mh-extra.com/html/koden/mdc-7010/mdc-7010_operation-manual_1984784191.webp)
MDC-7000/7900 Series
Chapter 9 Simple fault diagnosis
0093169010-10
9-15
No off center.
In the maximum range, off center function was
disabled.
Tracking malfunction. BRG T
As the result of TT test, the accuracy of bearing
has exceeded the reference.
Tracking malfunction. RNG
As the result of TT test, the accuracy of range
has exceeded the reference.
Tracking malfunction. CPA
As the result of TT test, the accuracy of CPA
has exceeded the reference.
Tracking malfunction. TCPA
As the result of TT test, the accuracy of TCPA
has exceeded the reference.
Tracking malfunction. T CRS
As the result of TT test, the accuracy of true
course has exceeded the reference.
Tracking malfunction. T SPD
AS the result of TT test, the accuracy of true
speed has exceeded the reference.
Time to trial manoeuvre is less than 30 seconds.
The remaining time of trial manoeuvre is less
than 30 seconds.
Reference target overload.
Attempted to acquire reference target beyond 3.
Do not use MAN COG/SOG.
Cannot use AIS with COG/SOG data inputted
by manual.
Do not use REF COG/SOG.
Cannot use AIS with COG/SOG data calculated
by reference target.
Do not use CURRENT COG/SOG.
Cannot use AIS with SET/DRIFT data inputted
by manual.
Do not use MAN STW.
Cannot use AIS with speed data inputted by
manual.
Do not use MAN POSITION.
Cannot use AIS with own ship position data
inputted by manual.
Time error.
Cannot use AIS with no time data.
Do not use MAN OFFSET POSITION.
Cannot use AIS with offset positon inputted by
manual.