MDC-7000/7900 Series
Chapter 9 Simple fault diagnosis
0093169010-10
9-5
9.4
No AIS display
This procedure is applied when AIS is not displayed.
First, confirm that [INPUT RNG] is properly set.
Targets outside of [INPUT RNG] are not displayed.
Confirm AIS function by following steps.
1
Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [BITE] => [DIAGNOSE AIS] =>.
2
Confirm that the [ ] mark appears at the left side of [AIS DATA], [HDG], [SPD], [LAT/LON] and
[COG/SOG].
3
Turn trackball to the left to complete.
If [x] mark is displayed in step 2, then
In the case of [AIS DATA]: No valid AIS data input.
Confirm AIS receiver connected to Display unit.
AIS DATA is usually input to AIS (J2) connector.
In the case of [HDG]: No valid HDG input.
Confirm HDG input of Display unit.
HDG is usually input to GYRO connector.
In the case of [SPD]: No valid SPD input.
Confirm SPD input of Display unit.
SPD is usually input to SDME (J6) connector.
In the case of [LAT/LON]: No valid LAT/LON input.
Confirm LAT/LON input of Display unit.
LAT/LON is usually input to EPFS (J5) connector.
In the case of [COG/SOG]: No valid COG/SOG input.
Confirm COG/SOG input of Display unit.
COG/SOG is usually input to SDME (J6) or EPFS (J5) connector.