Chapter 9 Simple fault diagnosis
MDC-7000/7900 Series
0093169010-10
9-4
9.3
TT is not operational
This procedure is applied when acquisition operation does not start despite ACQ key being pressed.
First, confirm that [INPUT RNG] is properly set.
The targets outside of [INPUT RNG] will not be acquired.
This procedure confirms ATA function.
1
Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [BITE] => [DIAGNOSE TT] =>.
2
Confirm [ ] mark appears on the left side of [HDG].
3
Turn trackball to the left to complete.
If [x] mark is displayed in step 2, then confirm HDG input for Display unit.