![Koden MDC-7010 Operation Manual Download Page 133](http://html.mh-extra.com/html/koden/mdc-7010/mdc-7010_operation-manual_1984784133.webp)
MDC-7000/7900 Series
Chapter 4 Target (AIS,TT and Trial manoeuvre)
0093169010-10
4-29
TEST TGT ON
By turning TEST TGT [ON], a large character [X] is displayed at the lower middle of the display.
A small character [x] is displayed in Target position.
Turn on TEST TGT, press STBY / TX key, and start transmission. Then, a target appears.
A target appears near the direction 10° and range 12 NM. After approaching to own ship, the target
moves toward direction 207°.
Own ship's speed is about 42 kn and the target speed is about 32 kn (Relative speed is 74 kn).
x
S
Target
12NM
1
Press MENU
key to display “Menu”.
Select [TARGET] => [TT] => [TEST TGT] => [ON], and press ENT key.
Range is fixed at 12 NM and cannot be changed.
2
Press STBY / TX key to start transmission.
X