KDS-6000BB
Chapter 1 Installation
0092660002-06
1-21
To prevent electric corrosion, connect a wire between the flange and
the ship
’s ground.
Fig. 1.25 Connection of a wire between the flange and the ship
’s ground
*
After completion of the installation, please confirm that the voltage between
the Flange and the ship
’s ground does not exceed 0.65V.
When the voltage is high, connect with a thicker power cable to reduce the
voltage under the specified value. If the voltage remains high, the Transducer
unit may be damaged due to electric corrosion.
warning
GND