KDS-6000BB
Chapter 1 Installation
0092660002-06
1-9
1.5.2 Maintenance space for TD tank
(1) When installing the TD tank, pay full attention to the safety (strength, waterproofness, etc.)
and, at the same time, secure a space for maintenance and inspections.
Since the Hull unit is not waterproof structure, keep it away from water drops and
splashes.
When KDS-6000BB is shipped from the factory with a standard, the length of the TD
tank and TD shaft are set as follows:
TD tank: 1230 mm (Standard)
TD shaft: 1411 mm (Standard)
When standard TD tank is installed with shortened length, the TD shaft length should
be processed at least
Fig. 1.10 Installation of TD tank
TD tank length (Lt) + 181 mm
Install the unit so that the
flange comes above the
draft at full load.
TD tank
Keel
50 mm or less: It should not project beyond the keel end.
Lt
TD tank length
(670 mm or more)
Lt + 535
If a work space of (Lt +
535) is not available,
provide a hole of a size
of at least 300 x 300mm
in the ceiling.
TD shaft
Draft line at full load
Install at 50 mm or more
higher than the draft line