1.5 Installation of Hull unit
1.5.1 Installation location of Hull unit
(1) Select a location the least influenced from air bubbles, interference or noise.
Install the Hull unit on the keel within the range of 1/3 to 1/2 of the overall length from
the bow.
Alternatively, install the unit so that the center of TD tank positions within 1 m from the
center of the keel.
Install the unit so that the Flange comes above the draft at full load.
Fig. 1.9 Installation location of Hull unit
※
Be sure there are no obstacles to interfere the ultrasonic beam when the Transducer unit is
lowered.
※
Provide sufficient clearance around the TD tank to make maintenance and inspection work.
※
The bow mark (
Δ) on the hull unit flange should be installed facing the bow of the vessel.
However, if there may be any interference at maintenance or inspection works, install the
unit to face 180
˚ reverse direction (stern direction).
1 m
1 m
昇降部
1/2
1/3
トランクパイプ
Hull unit
TD tank
Satisfy the following conditions and also instructions of installation
manual in deciding the TD tank mounting site.
Fully discuss about the strength with the shipyard and the installer
before determining on the position and the method of installation
and necessary materials.
Caution:
Summary of Contents for KDS-6000BB
Page 1: ......
Page 2: ......
Page 18: ...External View KDS 6000BB xvi 0092660002 06 Remote controller RCW 14 Optional Unit mm inch...
Page 19: ...KDS 6000BB External View 0092660002 06 xvii Hull unit DHU 630 Unit mm inch...
Page 56: ...This page intentionally left blank...
Page 60: ...This page intentionally left blank...
Page 71: ......
Page 72: ......