background image

Chapter 1 Installation 

 

KDS-6000BB 

1-8 

 

0092660002-06 

1.5 Installation of Hull unit                                                                               

       

       

 

 

 

 

 

 

1.5.1 Installation location of Hull unit                                                                     

           

 

(1) Select a location the least influenced from air bubbles, interference or noise. 

  Install the Hull unit on the keel within the range of 1/3 to 1/2 of the overall length from 

the bow. 

  Alternatively, install the unit so that the center of TD tank positions within 1 m from the 

center of the keel. 

  Install the unit so that the Flange comes above the draft at full load. 

 

 

 

 

 

 

 

 

 

 

Fig. 1.9 Installation location of Hull unit 

 

 

 

 

 

 

 

 

 

Be sure there are no obstacles to interfere the ultrasonic beam when the Transducer unit is 
lowered. 
 

 

Provide sufficient clearance around the TD tank to make maintenance and inspection work. 
 

 

The bow mark (

Δ) on the hull unit flange should be installed facing the bow of the vessel. 

However, if there may be any interference at maintenance or inspection works, install the 
unit to face 180

˚ reverse direction (stern direction). 

1 m

1 m

昇降部

1/2

1/3

トランクパイプ

Hull unit 

TD  tank 

     

 

Satisfy the following conditions and also instructions of installation 
manual in deciding the TD tank mounting site. 

Fully discuss about the strength with the shipyard and the installer 
before determining on the position and the method of installation 
and necessary materials. 

Caution: 

Summary of Contents for KDS-6000BB

Page 1: ......

Page 2: ......

Page 3: ...hapter 1 6 0092660002 06 2017 11 02 Chapter 3 7 8 9 10 Document No Revised Version Norm When part of the document needs to be revised the document has advanced revision number The document No is indic...

Page 4: ...es and some parts may be omitted Koden is not liable for damages and troubles arisen from misunderstanding of the contents in this manual Koden is not liable for any damages caused by earthquake light...

Page 5: ...ms on equipment Be careful of high voltage inside A high voltage which may risk your life is used This high voltage remains in the circuit after you have powered off switch To prevent touching the hig...

Page 6: ...ay leads to trouble fire smoking or electric shock In case of trouble contact our dealer or our company In case of smoke or fire boat power off and the power of this unit It may cause fire electric sh...

Page 7: ...essor unit 1 3 1 4 Installation of an Operation unit 1 4 1 4 1 Desk top installation of Operation unit 1 4 1 4 2 Flush mount installation of Operation unit 1 6 1 4 3 Installation of TD position alarm...

Page 8: ...3 1 3 2 Cleaning 3 1 3 2 1 Monitor Processor units 3 1 3 2 2 Hull unit 3 2 3 3 Fuse replacement 3 2 3 4 Diagnostics of troubles 3 2 3 4 1 Necessary information for requesting repair 3 2 3 4 2 System...

Page 9: ...cable Onboard AC power supply 100 115VAC 200 230VAC AC power cable VV 2D8 3M CW 373 5M CW 376 5M POWER 3P J6 8P J2 12P J1 5P CW 259 2M Hull unit control cable CW 593 20M TD position alarm Ext Sync Bo...

Page 10: ...t DOU 620 With mounting bracket and 5m cable 1 1kg 1 2 2 Operation unit DOU 620R With mounting bracket 5m cable and Remote controller RCW 14 with 5m cable DOU 620 1 1kg RCW 14 0 31kg 3 TD position ala...

Page 11: ...R E English 1 10 Installation manual KDS 6000BB IM E English 1 No Name of item Type Remark Weight Length Qty 1 TD tank ESR 1506 PVC 1230mm 30927C 2 PVC 1500mm 30927C 3 PVC 1800mm ESR 1507 FRP 1500mm S...

Page 12: ...kg 1 2 DC power cable CW 275 10M Cable is built into the Hull unit 10m 1 3 Hull unit control cable CW 593 20M Cable is built into the Hull unit 20m 1 d DHU 6302 Transducer unit Package 2 1 No Name of...

Page 13: ...ength Qty 4 Crank handle OB 03 1 Grease 100g 1 Fuse F 7161 4A F 7161 8A At input of 12 V At input of 24 V EACH 3 ANP base ANP 1 2 Binding Band AB 100 1000 2 5 Damper 34924D 1 Fixing collar 32681D 2 Sh...

Page 14: ...ucer unit DHU 6302 by holding its cable Such manner may cause breakage of the equipment No Name of item Type Remark Weight Length Qty 1 Transducer unit DHU 6302 With 10m cable With 18 pin water resist...

Page 15: ...wer rectifier PS 010 With 2 pieces of 5A fuse 5 AC power cable VV 2D8 3M Both ends plain 6 Connecting cable CW 372 5M 5m With 5 pin water resistant connector and one end plain CW 373 5M 5m 6 pin water...

Page 16: ...External View KDS 6000BB xiv 0092660002 06 External View Processor unit DPU 610 Processor unit DPU 610ST Sona ToneTM model Processor unit DPU 610ST Sona ToneTM model Unit mm inch...

Page 17: ...KDS 6000BB External View 0092660002 06 xv Operation unit DOU 620 TD position alarm Ext Sync Box JB 36 Unit mm inch Installation dimensions...

Page 18: ...External View KDS 6000BB xvi 0092660002 06 Remote controller RCW 14 Optional Unit mm inch...

Page 19: ...KDS 6000BB External View 0092660002 06 xvii Hull unit DHU 630 Unit mm inch...

Page 20: ...to 31 2 VDC m ft fm l fm NMEA0183 DBT DPT GGA GLL MTW RMC TLL VTG ZDA Display resolution Output power RMS Output frequency Tilt angle 70 W or less 24 VDC 70 W or less 24 VDC Output data format and se...

Page 21: ...ge has been found contact the dealer you purchased of our sales company 1 1 2 Appearance verification of each unit and accessories Inspect the appearance of each components and accessories and check t...

Page 22: ...ics equipment is expected to be less See Fig 1 1 Fig 1 1 KDS 6000BB Connection of power line 1 1 5 Confirmation after installation Be sure to confirm the following points before starting The confirmat...

Page 23: ...nents and the completion of power cabling works for them 1 3 Installation of KDC 6000BB Processor unit The Processor unit can be installed on either on table or panel Install by the following procedur...

Page 24: ...here installation plinth is installed See Fig 1 3 3 Remove 4 plastic corner guard caps of the Operation unit These can be easily pulled out upwards 4 Fix the clamps to the Operation unit with M4 screw...

Page 25: ...DS 6000BB Chapter 1 Installation 0092660002 06 1 5 On installing on desktop keep the maintenance space is required as shown below Unit mm inch Fig 1 4 Maintenance space of desk top installation Cautio...

Page 26: ...ing hole 4 Put the Operation unit and connected cable into the mounting hole and set it to the position in which the Operation unit becomes parallel to the install panel Fig 1 5 5 Install the Operatio...

Page 27: ...ition alarm Ext Sync Box within the hearing range in the vicinity of the Processor unit 2 Install it at a place where there is no water drops and enough maintenance space is available Fig 1 7 External...

Page 28: ...e sure there are no obstacles to interfere the ultrasonic beam when the Transducer unit is lowered Provide sufficient clearance around the TD tank to make maintenance and inspection work The bow mark...

Page 29: ...nk and TD shaft are set as follows TD tank 1230 mm Standard TD shaft 1411 mm Standard When standard TD tank is installed with shortened length the TD shaft length should be processed at least Fig 1 10...

Page 30: ...should stay level during standard cruise Apply FRP sufficiently to all the necessary sections to prevent leakage of water Make the surrounding of the TD tank projecting out from the bottom in a strea...

Page 31: ...he keel in the bottom Install the TD tank into the hole The Flange surface of the TD tank should stay level during standard cruise Make the surrounding of the TD tank projecting out from the bottom in...

Page 32: ...Chapter 1 Installation KDS 6000BB 1 12 0092660002 06 Apply FRP sufficiently to all the necessary sections to prevent leakage of water Fig 1 13 Example of TD tank installation 2...

Page 33: ...and finish it with 1 mm taper 3 Make 4 holes of 3 4 mm diameter at 90 apart around the TD shaft 5 mm down from the cutoff surface and provide M4 tapping Fig 1 14 Processing of TD shaft When the lengt...

Page 34: ...ng agent to prevent electric corrosion After fastening of the TD shaft to the Transducer unit please mark up the Bow mark at the top end of the TD shaft Fig 1 16 Assembling Hull unit 1 Covering 4 Cap...

Page 35: ...nsert the 3 shaft guides over the TD shaft in the direction as shown in the drawing below Insert a Fixing collar and fasten with 2 pieces of attached cap bolts to allow a little movement of the shaft...

Page 36: ...of the TD tank other than 1230mm long In the use case of other TD tank ensure the lowest part of the Transducer unit is at least 50mm above the lowest part of the TD tank To prevent slip out of the T...

Page 37: ...and Lock nut Lift up the Lock nut as shown in the left side figure below Tighten the Waterproof nut firmly by hand into the Flange opening Turn the waterproof nut 180 by striking a flathead screwdriv...

Page 38: ...to confirm the alignment when making the final clamping evenly at the position of smooth vertical movement Please apply grease to the gear of Hull unit and flange bearing part regularly Apply the Flan...

Page 39: ...sducer unit to an approximate position please adjust the unit with this lower limit switch When the limit switch is raised please fix the wires by ANP base and the binding bands attached so as to prev...

Page 40: ...ard power source 1 Turn the Hoist switch off and remove the main fuse of the Hull unit 2 Open the upper cover by removing the two fixing screws with a Phillips head screwdriver 3 Take off the gear ind...

Page 41: ...n the flange and the ship s ground After completion of the installation please confirm that the voltage between the Flange and the ship s ground does not exceed 0 65V When the voltage is high connect...

Page 42: ...tor TD position alarm Ext Sync Box JB 36 J2 12 pin connector Transducer unit extension cable CW 590 15M J8 6 pin connector NMEA1 input output GPS plotter etc J7 16 pin connector Operation unit DOU 620...

Page 43: ...3 2 1 Power input 2 Power input 3 Shield POWER External trigger input GND External trigger output GND 2 UP alarm J1 1 4 5 3 2 Caution Please be careful that each wire would not contact the ship s hul...

Page 44: ...sor unit DPU 610 Connection of DC power cable CW 259 2M Fig 1 29 Connection of a DC power cable R G B NC GND R GND G GND B GND NC NC NC NC H SYNC V SYNC NC Power input Power input Shield To POWER conn...

Page 45: ...ause heat generation or fire After completion of connection please confirm that a voltage between the Flange of the Hull unit and the ship s ground does not exceed 0 65V When the voltage is high conne...

Page 46: ...ected to this unit 12 V power 4A fuses 24 V power 8A fuses Fuses are mounted on the power connector For replacement please use the specified fuses without fail Connecting cable for the limit switch an...

Page 47: ...Power input White terminal Black terminal J8 NMEA1 Input output USB TD position alarm Ext Sync Box J5 External monitor External Echo sounder Cable for CW 412 5M keyboard 5 m J1 J2 J5 POWER J8 GND GND...

Page 48: ...been connected at shipping from factory 1 Connection to the TD position alarm Ext Sync Box JB 36 and J1 of the Processor unit DPU 610 Fig 1 32 Connection of KDS 6000BB TD position alarm Ext Sync Box T...

Page 49: ...d by synchronizing the KDS 6000BB transmission with the trigger of the external echo sounder Refer to the following for the connection Fig 1 33 Connection of an external echo sounder JB 36 Wind the in...

Page 50: ...the Display unit Fig 1 34 Connection of Display unit Connection of External monitor J5 Owner supply When installing an external monitor VGA monitor analog RGB input connect it via CCCW 576 0 5M to J...

Page 51: ...figure below Wire the cables with the CW 376 5M option as shown in the following color chart Connector Pin Remarks L8 1 GND 2 NMEA TX 3 NMEA TX 4 NMEA RX 5 NMEA RX 6 15V CW 376 5M To J8 of Processor u...

Page 52: ...t connected Without the cap the Processor unit may cause failure Fig 1 36 Connection of USB memory Connection of External Speaker Connect the External Speaker NP 108 optional to the Processor unit by...

Page 53: ...xternally connected equipment 1 Press to be displayed Menu3 2 Turn knob left to select Baud rate 3 Press knob left or to move setting value box 4 Turn knob left to select the setting value from 4800 9...

Page 54: ...nal output 3 Press knob left or to move setting value box 4 Turn knob left to select the setting value from On or Off On Enable the output Off Disable the output 5 To set other output repeat the steps...

Page 55: ...tude GGA RMC GLL Date ZDA RMC Heading HDT HDG HDM VTG RMC Time ZDA GGA Speed VTG RMC 1 7 2 Output sentences The sentences of DBT DPT GGA GLL MTW RMC TLL VTG and ZDA can be transmitted The output forma...

Page 56: ...This page intentionally left blank...

Page 57: ...t be detected or when the bottom is of mud pool or seaweed Gain TD shall be turned up When transfer to fish schools etc frequently occurs Gain TD shall be turned down Adjustment shall be made under co...

Page 58: ...to 100 In crowded fishing areas this function may be used to reduce power and avoid interference to other fishing boat s sonars and echo sounders 100 indicates the maximum power and then gradually red...

Page 59: ...ft or to move setting value box 4 Turn knob left to select the setting value from 180 00 to 180 00 5 Press to close the menu Example How to correct the bow direction 90 setting 1 Turn knob left to sel...

Page 60: ...This page intentionally left blank...

Page 61: ...and keep good contact 3 2 Cleaning 3 2 1 Monitor Processor units Contamination on the screen may cause faint images For cleaning the screen wipe it with soft and clean cloth dipped in diluted neutral...

Page 62: ...3 4 Diagnostics of troubles In this section simple procedures to find out troubles are mentioned to locate the troubles on boat 3 4 1 Necessary information for requesting repair Please inform of the...

Page 63: ...card check 7 Baud rate of Transducer unit 8 Communication state of Processor unit At normal Count of number of OK At abnormal Count number of NG 9 Receiving data 10 Confirmation of voltage Transducer...

Page 64: ...menus are as follows 1 Demo files Sonar 2 Demo file bottom scan 3 Demo files Echo sounder ROM 1 Demo files Sonar Demo file bottom scan ROM1 Demo files echo sounder ROM 1 Cancel Execute Menu System che...

Page 65: ...in adjustment Save start Demo file echo sounder Cancel Execute Menu System check Initialize Demo file sonar Demo file bottom scan Wake erase Delete files Tilt origin adjustment Save start Demo file ec...

Page 66: ...rectory of the USB memory 2 Insert the USB memory into the USB connector provided on the back panel of KDS 6000BB Processor unit DPU 610 Do not use a USB Hub because it may lead to failures 3 Turn pow...

Page 67: ...e press GAIN key 9 If a file is found the selected item is displayed 10 Select the file to be updated and press 11 Select Execute and press Update starts Please wait for a while Searching USB F35 V010...

Page 68: ...en appears After the above screen has been displayed try again the update without switching off the power When USB memory is changed press GAIN key to search the software Repeat the steps of Items 8 t...

Page 69: ...lected in KDS 6000BB main body The files of F35 XXXXX SAV are searched through USB route folder Plural files can be selected by renaming of F35 SET00 SAV files XXXXX is arbitrary alphabets or numerica...

Page 70: ...cessor unit and Hull unit Please report to the selling agent or a sales office Interference and noise are severe The Transducer unit system is faulty Interference from echo sounders on other ships Che...

Page 71: ......

Page 72: ......

Reviews: