3-8
FUNCTION SETTINGS
4. PULSE WIDTH
The transmitted pulse width can be set.
The transmitted pulse can be set to these three (narrow, normal, wide), where the
optimum setting will be applied according to the range automatically.
Or it can be set manually, if a specific pulse width (0.1 to 3.6 msec) is required.
Each press of [
←
] or [
→
] key changes the setting, "NARROW, NORMAL, WIDE,
0.3ms."
Select the desired value, and then press the Enter key.
NORMAL
:
Setting NORMAL changes automatically according to the range.
NARROW
:
When the searching range is short and higher resolution is required,
the pulse width should be set NARROW.
WIDE
:
The longer range gives less resolution.
CONSTANT
:
The initial value of the pulse width is 0.3 ms. The pulse width is to
be set every 0.1 ms unit from 0.1 to 3.6 ms.
Use [
↑
] key to select the larger value.
Use [
↓
] key to select the smaller value.
NOTE !---------------------------------------------------------------------------------------------------------
In actual practice, the shorter pulse (narrower) gives better resolution, and
Less noise in shallow water or surface scanning. The longer pulse (wider)
will reach deeper but give less resolutions.
----------------------------------------------------------------------------------------------------------------------
5. TX POWER
The output power of the ultrasonic sound wave may be selected.
In crowded fishing areas, this function may be used to reduce power and avoid
interference to other Fishing boat's Sonars and Echo Sounders.
Each press of [
←
] or [
→
] key change the setting, "LOW or HIGH."
Select the desired level of the transmitting power, and then press the Enter key.