Troubleshooting and Error Messages
6– 4
16FEB01 – 7E6174
•
•
If incoming wash water is dirty, clean the Wash
Rack, Wash Tank, and Water Reservoir
thoroughly. Have the incoming water Filter
changed. Be sure that the correct water Filter is
used.
•
•
•
Check incoming water temperature.
Temperature must be between 4
°
C (40
°
F) and
29
°
C (85
°
F).
•
If 10 x 10 cm films fail to transport reliably, feed
the sheets of films diagonally. For DFF only.
•
Check that solution Level Probes are clean and
free from buildup. Check that all external
replenishment lines (i.e. those who are outside
of the Multiloader) are without kinks or air
bubbles.
Transport Failure
Surface Artifacts
Abnormal Film Densities
Wet Films
Low Solution Levels
Overlapping of Films
Summary of Contents for X-OMAT 7000
Page 4: ...4 16FEB01 7E6700...
Page 6: ...6 16FEB01 7E6174...
Page 20: ...Introduction 1 14 16FEB01 7E6174...
Page 32: ...Quick Reference Operating Instructions 2 12 16FEB01 7E6174...
Page 48: ...Overview 3 16 16FEB01 7E6174...