5-12
A-61601 June 2012
Adjusting the pre-
separation roller
tension
If you are experiencing multi-feeds or document jams, it may be
necessary to adjust the pre-separation roller tension.
1. Remove the separation module from the scanner by following the
steps described previously in “Replacing the separation module and
tires”.
2. Locate the spring on the separation module.
3. Lift the spring from the holder and move it to the left or right as
desired to adjust the tension.
4. When finished, reinsert the separation module by aligning the tabs
with the slots and snapping it into position.
Supplies and
consumables
Contact your scanner supplier to order supplies.
NOTE: Items and catalog numbers are subject to change.
Description
CAT No.
Kodak
Feed Rollers (qty 12)
148 4864
Kodak
Gentle Photo Separation Module
169 5097
Kodak
Picture Saver Standard Separation Module
196 0426
Kodak Digital Science
Roller Cleaning Pads (qty 24)
853 5981
Kodak Digital Science
Transport Cleaning Sheets (qty 50)
169 0783
Brillianize
Detailer Wipes / for
Kodak
Scanners
826 6488
Kodak
Legal Flatbed Accessory
119 9470
Kodak
A3 Flatbed Accessory
818 2271