DIAGNOSTICS
Error Codes
10DEC05
DG4825-1
Page
75 of 180
12112 - SLOW SCAN did not move
12113 - SLOW SCAN CONTROLLER BOARD A6: NVRAM malfunctioned
12115 - SLOW SCAN CONTROLLER BOARD A6: Software Error
12116 - SLOW SCAN CONTROLLER BOARD A6 did not communicate with
MSC
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Cause 1: The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Cause 2: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action:
Do the checkout for the
MOTION SYSTEM CONTROL BOARD A1
Description: The SLOW SCAN AY did not stop moving before the next command to
move. This error indicates a communication error with the SLOW SCAN
CONTROLLER BOARD A6.
Cause 1: The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Cause 2: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action:
Do the checkout for the