DIAGNOSTICS
Checkout Procedures
10DEC05
DG4825-1
Page
126 of 180
17
If the status of a SENSOR does not match the table, do the corresponding checkout.
18
Press [LATCH POSITION].
19
If:
•
DUPLEX CAM does not move, do the checkout for the
•
HOOKS are not in the down position, do the checkout
•
EXTRACTION BAR is not in the home position, do
20
Check the status of the SENSORS and LEDs.
21
If the status of a SENSOR does not match the table, do the corresponding checkout.
22
Press [UNLATCH].
SENSOR
Status
LED
Checkout
EXTRACTION BAR SENSOR
S9
X
DS28
illuminated
CAM INNER SENSOR S10
X
DS26
illuminated
CAM OUTER SENSOR S11
DS27 not
illuminated
SENSOR
Status
LED
Checkout
EXTRACTION BAR SENSOR
S9
X
DS28
illuminated
CAM INNER SENSOR S10
DS26 not
illuminated
CAM OUTER SENSOR S11
X
DS27
illuminated