12004 - PLATE PRESENT SENSOR S5 failed to activate
12009 - Caution! SLOW SCAN MOTOR drawing too much power
Cause 1: The PLATE PRESENT SENSOR S5 operates correctly, but another malfunction
occurred.
Action:
1.
Check:
•
PLATE was removed from the CASSETTE
•
SLOW SCAN MOTOR operates correctly
2.
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
3.
Remove any obstructions from the path of the EXTRACTION BAR.
Cause 2: The PLATE PRESENT SENSOR S5 malfunctioned.
Action:
Cause 3: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action:
Do the checkout for the
MOTION SYSTEM CONTROL BOARD A1
Cause:
A malfunction occurred in one or more of the following components:
•
COIL BOARD
•
EXTRACTION BAR SENSOR S9
•
SLOW SCAN AY
Action:
1.
Check for an obstruction.
2.