Operation
SIMDOS diaphragm metering pump
KNF Flodos BA_SIMDOS_EN_02_160044.docx
20
Translation of original operating manual
Displays the set flow rate (
1
) if the unit (
2
) has been set on
“ml/min”.
Displays the metering volume (
1
) if the unit (
2
) has been set on
“ml”.
Displays the pump running time.
Upward count (3) if no timeout has been programmed.
Elapsed time display.
Downward count (3) if a timeout (metering) has been
programmed. Time remaining display.
Display of delivery volume (
4
) since last pump start-up.
Displays whether pump external drive has been activated, and the
external drive condition (
5, 7, 8, 9
).
Displays whether pump has been set on Autostart (
6
).
Displays whether the pump is operating, stopped or paused (
10
).
7.4. Switching the pump on and off
The default setting is for the pump to remain off when the mains
power supply is switched on.
Switch on
Briefly press the “STOP” button – the pump will switch on.
The display lights up, and the pump is ready for use.
Switch off
Hold the “STOP” button down for at least 2 seconds.
The pump will now switch off completely.
Standby
When the pump is stopped, after ten minutes without any user
input the device switches into standby condition (display goes
dark).
However, the pump is still ready for use immediately when
required.
Press “STOP” or any other key to reactivate the pump from
standby condition.
The external drive reactivates the pump from standby as soon
as a control signal is present.
Specified flow and unit
Time counter
Volume meter
External drive
Auto start
Operating condition
Fig. 17: Switching the pump on
Hold down for 2 seconds
Fig. 18: Switching the pump off