Technical specifications
• USB V1.1 & V2.0 full speed compatible.
• Power supply: Output of 6V (2 A max), regulated or switched dc with a positive centre and a
negative outer pin.
• 2 x analogue inputs & 4 x digital inputs.
• 6 x digital outputs & 2 x motor drive outputs.
• 256 byte programmable memory for standalone operation.
• Suitable for use in a 0 – 40ºC operating range and 0 - 95% RH (non-condensing).
• Dimensions: H: 5.9”, W: 8.7”, D: 1.4”.
• Weight: 12.3oz (350g).
Please note:
• The K’NEX Interface contains no user serviceable parts.
• Using the K’NEX Interface in a way that is outside its normal operation (as described in this
manual) may impair the unit’s protection and ability to function correctly.
Troubleshooting
Problem:
When I click on the Connect icon I get a ‘Communications Error: Could not connect
to the interface’ message.
1. Disconnect the power supply, re-connect and try again.
2. Check that the interface is powered and the green LED is on.
3. The USB lead is connected both to the USB port on the interface and the USB port on the
computer.
4. The green LED next to the GO button is lit solid green (if it’s flashing press the GO button once).
5. The Interface/Connection selection is correct (select Interface from the communications error
message or from the File menu).
6. The USB drivers have installed correctly (see below).
If it still fails to respond, please contact the Technical Support department at K’NEX Education.
Please provide details of:
• The computer platform it is being used with
• The software and its version number
• A description of the problem being encountered
If possible, telephone from a location where you can operate The K’NEX Interface with the computer.