
44
97-1129-01 Rev. D
www.kistlermorse.com
29 cal (calIBraTIon) dISplay
Accessing this menu allows you to view the calibration values that have been entered or internally calculated, as
shown in Table4. Follow this procedure to display the calibration parameters:
1. If the SVS2000 is in Run Mode, press the ‘2’ Key, ‘9’ Key, and Enter Key to access the menu tree. The
display shows:
29 CAL DISPLAy
2. Press the enter key to access this menu. The display looks like this:
Cnt/mV 699
3. Press the Arrow Keys to scroll through the other calibration display parameters.
4. Press the Gross or net Key to return to Run Mode.
Table 4. Calibration Display
Calibration Parameter
Description
Cnt/mV
digital counts per millivolt of signal
ScfWgt 1
scale factor weight
[entered scale factor weight
from Manual Cal
or
(hi span weight - lo span weight)
from Auto Cal]
ScfCnt 1
scale factor counts
[entered scale factor counts
from Manual Cal
or
(hi span counts - lo span counts)
from Auto Cal]
ZeroCnt
zero counts = digital counts
corresponding to zero weight
DispVCW 2
entered display value
correction weight
HiSpanW 2, 3
entered hi span weight
LoSpanW 2, 3
entered lo span weight
HiSpanC 2, 3
hi span counts = digital counts
corresponding to hi span weight
LoSpanC 2, 3
lo span counts = digital counts
corresponding to lo span weight
0mV_Cnt
digital counts corresponding
to 0 millivolts of signal
Summary of Contents for SVS2000
Page 1: ...SVS2000 Installation Operation Manual IOM97 1129 01 Rev D...
Page 2: ......
Page 10: ...6 97 1129 01 Rev D www kistlermorse com...
Page 11: ...7 www kistlermorse com 97 1129 01 Rev D...
Page 12: ...8 97 1129 01 Rev D www kistlermorse com...
Page 13: ...9 www kistlermorse com 97 1129 01 Rev D...
Page 14: ...10 97 1129 01 Rev D www kistlermorse com...
Page 20: ...16 97 1129 01 Rev D www kistlermorse com Figure 3 Wiring Diagram Current Output Card venture...