24
97-1129-01 Rev. D
www.kistlermorse.com
neT WeIghT dISplay
The net weight is the change in weight since the last tare. To tare the vessel:
1. While in Run Mode, press the Tare Key for 1 second.
2. If you set up a user Access Code the display shows:
USER CODE?
Enter the User Access Code. Press the Enter Key.
3. The display briefly shows:
TAre ImPLemenTeD
ToTal WeIghT dISplay
The total weight is the algebraic sum of the net weights. It is updated each time the vessel is tared.
zero ToTal WeIghT
To reset the total weight to zero:
1. use an Arrow key to scroll to the total weight display. The display looks like this:
TOT 12345600 lbs
2. Press the Zero key. The display shows:
ZerO TOTALIZer?
3. Press the Enter Key to zero the totalizer. Press any other key to abort this function.
4. If you set up a user Access Code (see Service menu) the display shows:
USER CODE?
Enter the User Access Code. Press the Enter Key.
5. The display briefly shows:
TOTALIZer CLeArD
dISplay nuMBer oF TareS
To display the number of tares that have occurred since the total weight was reset:
1. use an Arrow key to scroll to the total weight display. The display looks like this:
TOT 12345600 lbs
2. Press the enter key. The display briefly looks like this:
#TAres: 21
Summary of Contents for SVS2000
Page 1: ...SVS2000 Installation Operation Manual IOM97 1129 01 Rev D...
Page 2: ......
Page 10: ...6 97 1129 01 Rev D www kistlermorse com...
Page 11: ...7 www kistlermorse com 97 1129 01 Rev D...
Page 12: ...8 97 1129 01 Rev D www kistlermorse com...
Page 13: ...9 www kistlermorse com 97 1129 01 Rev D...
Page 14: ...10 97 1129 01 Rev D www kistlermorse com...
Page 20: ...16 97 1129 01 Rev D www kistlermorse com Figure 3 Wiring Diagram Current Output Card venture...