70
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130318002
Chapter 6 - SuperFlow® 350 Regulator & Exhaust System Post Dive Cleaning & Sanitizing
Kirby Morgan
®
37SS
5) Using the soap solution, wet the exhaust valves
and seats as well as the water dump valve and valve
seat surfaces as well as all surfaces exposed to the
diver's exhalation. The water dump valve can be dif-
ficult to see so take extra care to be sure it is cleaned.
Agitate surfaces with the rag and/or brush, then rinse
with freshwater.
Make sure the solution flows through the rear of the
regulator where the oral/nasal attaches to the mount
nut. This will help to ensure the exhaust valve in the
regulator gets cleaned.
6) After cleaning with soap, Carefully inspect every-
thing that has been cleaned for any obvious signs of
deterioration or damage, replace any components in
question.
Inspect the exhaust valves on a regular basis.
6.6.2 Sanitizing
Sanitizing is done to minimize the spread of germs.
The helmet should be sanitized daily when used by
one diver, and between dives when used by multiple
users.
To maximize germ killing action, all internal surfaces
that come in contact with the exhalation gas need to
be thoroughly wetted with the sanitizing solution and
kept wetted for at least 10 minutes then thoroughly
rinsed.
The exhaust valve inserts are recessed on one side to accept the exhaust valves so they sit flush in the inserts. The exhaust valves
must be installed properly in the inserts or they will not seal or perform properly.
Correct
WRONG