68
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130318002
Chapter 6 - SuperFlow® 350 Regulator & Exhaust System Post Dive Cleaning & Sanitizing
Kirby Morgan
®
37SS
6.5.4 Communications Inspection
Visually inspect the earphones, microphone, wires,
lugs, and communications posts if installed. Test
each component for proper operation. Connect to the
deck amplifier and talk back and forth. Replace any
weak earphone or microphone. Open the earphone
rubber covers and remove the protectors. Allow to
dry thoroughly. Replace defective earphones.
Good communications are vital to your safety. Regularly
inspect the components of the communications system and
replace when necessary.
6.5.5 Lubricate Nose Block O-rings
Tools Required:
7/16
inch Open End wrench
1) Unscrew the nose block device packing nut and
lubricate the two O-rings and nose block shaft. Re-
tighten the nut just to the point where the nose block
device will still slide, but requires a firm push or pull.
The nose block O-rings must be regularly lubricated.
2) Test the shaft to ensure that it will still slide freely
at this time. If it does not, loosen or tighten the
packing nut just enough to permit the shaft to slide
properly.
3) Retighten the nose block knob.
6.6 SuperFlow
®
350 Regulator &
Exhaust System Post Dive Cleaning
& Sanitizing
Purpose
This procedure should be performed at completion
of diving operations and/or whenever the helmet is
to be used by another user.
Tools Required:
¼" Flat blade attachment on torque screwdriver
Small Phillips screwdriver
Clean wiping rag
Nylon tooth brush
Spray bottle with detergent solution
Spray bottle with antiseptic cleaner
6.6.1 Post Dive Disassembly
1) Remove the demand regulator clamp by remov-
ing the clamp screw. Lift off the regulator cover and
diaphragm.