156
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130318002
Chapter 9 - Weld Shield Assembly
Kirby Morgan
®
37SS
Remove the two plug screws from the port retainer.
2) Insert the screws through the weld lens mount
B
WARNING
Use only the screws provided with the
Weld Lens Kit for installation of this
assembly. Longer screws will damage
the helmet shell and/or the threaded
inserts. This could cause flooding
through the port.
Install the screws through the mount ears.
3) With the shield facing out from the helmet or
mask, install and tighten the two mount screws into
the port retainer ears.
4) Tighten the two lock nuts on the ends of the hinge
studs so that the welding lens assembly can be flipped
up, but will not fall down from its own weight.
Tighten the weld lens assembly.
9.4 Weld Shield Assembly
9.4.1 Weld Shield Assembly Installation
Tools Required:
3/8
inch Open End Wrench
1/4
inch Flat Blade Attachment on Torque Screwdriver
1) Remove the two plug screws from the port re
-
tainer. Refer to the drawing included with the weld
shield assembly kit for the remainder of the location
numbers.
2) Insert the mount screws through the spacer washers
and then through the weld shield mount ears.
3) With the shield facing out from the helmet or
mask, install and tighten the two mount screws into
the port retainer.
9.5 Use of Quick Disconnect
A Quick Disconnect can be used with all bail-out sys
-
tems. It provides greater convenience on deck while
dressing the diver. It also makes it possible to separate
the attachment of the bail-out from the helmet should
the diver become entangled underwater. All quick
disconnects used must be of good quality and be