63
Kirby Morgan
®
37SS
Chapter 6 - General Cleaning & Inspection Procedures
Start removal of the cover by unscrewing the retainer ring.
Remove the retaining ring and regulator cover.
Remove the diaphragm.
To sanitize the breathing system properly, the regula-
tor clamp, screw and diaphragm must be removed so
that the interior of the regulator can be cleaned and
sanitizing solution can be flushed through the exhaust
valve and whiskers.
1) Remove the demand regulator clamp by removing
the clamp screw.
2) Lift off the regulator cover and diaphragm.
3) Sanitize the regulator interior and flush sanitizing
fluid through the whiskers. Rinse with fresh water.
4) Reinstall the diaphragm, cover, clamp and screw.
5) Tighten the clamp screw to the recommended
torque of 12 inch pounds using a torque screwdriver.
B
WARNING
Always sanitize the
helmet prior to use
by another person.
Failure to do could
result in the trans-
mission of commu-
nicable diseases,
some of which may
cause long term dis-
ability or death.
6.3.2.1 Mild Soap Solution for General
Cleaning and Leak Detector Use
Maintenance procedures include cleaning with a
general-purpose solution of a mild diluted hand dish
washing soap such as Joy
®
or Palmolive
®
. Cleaning
solution is prepared by mixing approximately one
teaspoon of soap to 1/2 gallon of warm fresh water.