1. General safety warnings and precautions

•  Cleaning and maintenance to be carried out by the user must 

not be carried out by unsupervised children.

•  Before working on the system (maintenance, cleaning), always 

disconnect the product from the mains power supply.

•  Check the system periodically, in particular all cables, springs 

and supports to detect possible imbalances, signs of wear or 

damage. Do not use, if repairs or adjustments are necessary, 

since installation failure or an incorrectly balanced automation 

may cause injury.

•  The packing materials of the product must be disposed of in 

compliance with local regulations.

•  When operating a biased-off switch, make sure that other 

persons are kept away.

•  When operating the gate, keep an eye on the automated 

mechanism and keep all bystanders at a safe distance until 

the movement has been completed.

•  Do not operate the product if anyone is working nearby; 

disconnect its power supply before permitting such work to 

be done.

•  If the power cable is damaged, it must be replaced by the 

manufacturer or by an appointed servicing company or 

similarly qualified person in order to prevent any form of risk.

1.2 - Installation warnings

•  Prior to installing the drive motor, check that all mechanical 

components are in good working order and properly 

balanced, and that the automation moves correctly.

•  If the gate or door being automated has a pedestrian gate, 

then the system must include a control device that will inhibit 

the operation of the motor when the pedestrian gate is open.

•  Make sure that the control devices are kept far from moving 

parts but nonetheless in a visible position. Unless a selector 

is used, the control devices must be installed at a height of at 

least 1.5 m and must not be accessible.

•  Ensure that entrapment between the driven part and the 

surrounding fixed parts due to the opening movement of the 

driven part is avoided.

•  Permanently fix the label concerning the manual release 

adjacent to its actuating member.

•  After installing the drive motor, make sure that the mechanism, 

protective system and all manual manoeuvres operate 

properly.

1.1 - General warnings

The following warnings are taken directly from the 

Regulations and apply, as far as possible, to the product 

described herein.

  ATTENTION! - Important safety instructions. Follow all 

instructions as improper installation may cause serious 

damage.

  ATTENTION! - Important safety instructions. It is 

important for you to comply with these instructions 

for your own and other people’s safety. Keep these 

instructions.

•  Before commencing the installation, check the “Technical 

characteristics” (in this manual), in particular whether this 

product is suitable for automating your guided part. If it is not 

suitable, DO NOT continue with the installation.

•  The product cannot be used before it has been commissioned 

as specified in the chapter on “Testing and commissioning”.

• 

ATTENTION! - According to the most recent European 

legislation, the implementation of an automation 

system must comply with the harmonised standards 

provided by the Machinery Directive in force, which 

enables declaration of the presumed conformity of the 

automation. Taking this into account, all operations 

regarding connection to the electricity grid, as well 

as product testing, commissioning and maintenance, 

must be performed exclusively by a qualified and skilled 

technician!

•  Before proceeding with the installation of the product, check 

that all the materials are in good working order and suited to 

the intended applications.

•  This product is not intended to be used by persons (including 

children) whose physical, sensory or mental capacities are 

reduced, or who lack the necessary experience or skill.

•  Children must not play with the appliance.
•  Do not allow children to play with the fixed control devices of 

the product. Keep the remote controls away from children.

• 

ATTENTION! - In order to avoid any danger from 

inadvertent resetting of the thermal cut-off device, this 

appliance must not be powered through an external 

switching device, such as a timer, or connected to a 

supply that is regularly powered or switched off by the 

circuit.

•  Provide a disconnection device (not supplied) in the plant’s 

power supply grid, with a contact opening distance permitting 

complete disconnection under the conditions dictated by 

overvoltage category III.

•  Handle the product with care during installation, taking care 

to avoid crushing, denting or dropping it, or allowing contact 

with liquids of any kind. Keep the product away from sources 

of heat and naked flames. Failure to observe the above can 

damage the product, and increase the risk of danger or 

malfunction. Should this happen, stop installation immediately 

and contact Customer Service.

•  The manufacturer assumes no liability for damage to property, 

items or persons resulting from non-compliance with the 

assembly instructions. In such cases the warranty for material 

defects is excluded.

•  The weighted sound pressure level of the emission A is lower 

than 70 dB(A).

Summary of Contents for INTROSMALL24/400

Page 1: ...canique pour l automatiser les portails battant Instructions et avertissements pour l installation et l utilisation DE Elektromechanischer Getriebemotor f r Automatisierungen von angeschlagenen Toren...

Page 2: ...ra n cessaires La reproduction partielle sans le consentement du Fabricant est interdite Les mesures fournies sont indicatives et non contraignantes La langue originale de r daction est l italien le F...

Page 3: ...assicurarsi che il meccanismo il sistema di protezione ed ogni manovra manuale funzionino correttamente 1 1 Avvertenze generali Le seguenti avvertenze sono trascritte direttamente dalle Norme e per qu...

Page 4: ...nte l anta del cancello in Apertura e in Chiusura verificare che il movimento avvenga con attrito uguale e costante in ogni punto della corsa non devono esserci momenti di maggiore sforzo Verificare c...

Page 5: ...della cassa di fondazione spingendolo fino alla fine della cassa e in modo tale da far combaciare i fori di fissaggio presenti sul motoriduttore con quelli della cassa stessa fig 12 11 Inserire nei f...

Page 6: ...guire la misura della forza d impatto secondo quanto previsto dalle norme EN 12445 ed EN 12453 Se il controllo della forza motore viene usato dalla Centrale come ausilio al sistema per la riduzione de...

Page 7: ...dere Tabella 1 La stima di durabilit viene effettuata sulla base dei calcoli progettuali e dei risultati di prove effettuate su prototipi Infatti essendo una stima non rappresenta alcuna garanzia sull...

Page 8: ...8 IT KING gates srl via Malignani 42 33077 Sacile PN Italy P I V A 01698760939 1245 INTROSMALL24 400...

Page 9: ...fety instructions It is important for you to comply with these instructions for your own and other people s safety Keep these instructions Before commencing the installation check the Technical charac...

Page 10: ...e gate label Moving the gate panel manually in Opening and in Closure check that the movement takes place with the same and constant friction in all points of the run there must not be moments of grea...

Page 11: ...e pushing it to the end of the case aligning the fixing holes present on the gear motor with those of the case itself fig 12 11 Insert the supplied screw fasteners into the holes fig 13 and tighten th...

Page 12: ...12445 and EN 12453 standards If the control of the driving force is used by the control unit as an auxiliary to the system for the reduction of the force of impact try and adjust the functions that o...

Page 13: ...product see Table 1 The estimation of duration is made on the basis of the design calculations and the test results performed on prototypes In fact as it is an estimate it does not represent any guara...

Page 14: ...14 EN KING gates srl via Malignani 42 33077 Sacile PN Italy P I V A 01698760939 INTROSMALL24 400...

Page 15: ...protection et toute manoeuvre manuelle fonctionnent correctement 1 1 Instructions g n rales Les recommandations suivantes sont transcrites directement des R glementations et dans la mesure du possible...

Page 16: ...du portail en Ouverture et en Fermeture v rifier que le mouvement ait lieu avec un frottement gal et constant en chaque point de la course il ne doit pas y avoir de moments de plus grand effort V rif...

Page 17: ...troduire alors le moteur l int rieur de la caisse de fondation en le poussant jusqu au fond de la caisse et de fa on faire co ncider les orifices de fixation pr sents sur le motor ducteur avec ceux de...

Page 18: ...e de la force d impact selon les dispositions pr vues par les normes EN 12445 et EN 12453 Si le contr le de la force moteur est utilis par la Centrale comme auxiliaire au syst me pour la r duction de...

Page 19: ...la base des calculs conceptuels et des r sultats de tests effectu s sur prototypes tant donn qu il s agit en effet d une estimation elle ne constitue aucune garantie sur la dur e effective du produit...

Page 20: ...r la base d une demande motiv e les donn es relatives la quasi machines dans le respect des droits de propri t intellectuelle Si la quasi machines a t mise en service dans un pays d Europe dont la lan...

Page 21: ...vorg nge ordnungsgem funktionieren 1 1 Allgemeine Hinweise Die folgenden Hinweise wurden direkt aus den geltenden Normen bernommen und sind soweit m glich auf das betreffende Produkt anwendbar ACHTUNG...

Page 22: ...ollieren Torfl gel manuell ffnen und schlie en und pr fen ob die Bewegung mit an allen Stellen des Weges gleicher und konstanter Reibung erfolgt es darf keine Stellen mit h herem Kraftaufwand geben be...

Page 23: ...Abb 11 10 Nun den Motor in den Fundamentkasten einsetzen Diesen dabei bis zum Anschlag in den Kasten schieben so dass die Befestigungsl cher am Tor ffner mit denen des Kastens zusammen passen Abb 12 1...

Page 24: ...ftmessung gem EN 12445 und EN 12453 durchf hren Wird die Kontrolle der Motorkraft von der Steuerung als Hilfe im System zur Reduzierung der Schlie kraft verwendet versuchen die Funktionen einzustellen...

Page 25: ...he Tabelle 1 Die Sch tzung der Standzeit erfolgt aufgrund der Planungsberechnungen und der Ergebnisse von an Prototypen ausgef hrten Versuchen Da es sich um eine Sch tzung handelt ist sie keine Garant...

Page 26: ...26 DE INTROSMALL24 400...

Page 27: ...nto asegurarse de que el mecanismo el sistema de protecci n y todas las maniobras manuales funcionen correctamente 1 1 Advertencias generales Las siguientes advertencias se transcriben directamente de...

Page 28: ...cancela en Apertura y en Cierre controle que el movimiento tenga lugar con una fricci n igual y constante en todos los puntos del movimiento no deben haber momentos de mayor esfuerzo Controle que la...

Page 29: ...a fig 11 10 En este momento introduzca el motor dentro de la caja de cimentaci n empuj ndolo hasta el final de la caja para hacer corresponder los agujeros de fijaci n presentes en el motorreductor co...

Page 30: ...a central de mando 12 Mida la fuerza de impacto seg n establecen las normas EN 12445 y EN 12453 Si el control de la fuerza del motor lo usa la Central como ayuda al sistema para la reducci n de la fue...

Page 31: ...del producto v ase Tabla 1 La estimaci n de durabilidad se realiza sobre la base de los c lculos de proyecto y de los resultados de pruebas realizadas con prototipos De hecho siendo una estimaci n no...

Page 32: ...32 ES KING gates srl via Malignani 42 33077 Sacile PN Italy P I V A 01698760939 INTROSMALL24 400...

Page 33: ...33 254 mm 72 5 mm 320 mm 81 mm 52 mm E F B H D D G G A A C C G 1 2 3 4...

Page 34: ...34 1 2 8 OK NO OK NO 8 A 5 7 6 8...

Page 35: ...35 90 90 180 9 10...

Page 36: ...36 11 12 13...

Page 37: ...37 Clack 3 2 1 14 15...

Page 38: ...38 5 4 3 2 1 A C B 180 16 17...

Page 39: ......

Page 40: ...etails Timbro Stamp Azienda Company Localit Address Provincia Province Recapito telefonico Tel Referente Contact person King Gates S r l Phone 39 0434 737082 Fax 39 0434 786031 info king gates com www...

Reviews: