PMX_MULTI
User’s Manual
45
Basic Functions | CONFIG Settings
CONFIG parameter details
The details of CONFIG parameters are provided below.
CF00 (
RST
)
Panel setting reset
Select this to set the following parameters to their factory default settings
. Then, press SET twice to
execute the reset.
CF01 (
PON
)
Output state when the power is turned on
Sets the output state that the PMX will be in when the power is turned on
. When you are using an
external contact to turn the output off, this parameter is invalid.
To apply the setting, turn off the power and then turn it back on.
Even when set to “
AUTO
,” if a load with accumulated energy, such as a battery, is connected, the output
may not turn on when the power is turned on even after the power is turned off with the output turned on.
CF02 (
MEM
)
Memory content display
Sets whether the PMX will show the saved contents in the memory before they are recalled.
• Output voltage
• Output current
• Overvoltage protection
• Overcurrent protection
• output-on delay/ off delay time
• Parallel operation and series operation
• Output state when the power is
turned on (CF01)
• External control for turning output on/off (CF04)
Display
Description
RST
Reset
Resets the panel settings
Display
Description
SAFE
Safe
The output is off (factory default setting)
AUTO
Auto
The output state that the PMX was in immediately before the
power was turned off
FORC
Force
Output on
Display
Description
OFF
oFF
Recall without showing the saved contents in the memory
ON
on
Recall after showing the saved contents in the memory
(factory default setting)