2
General Power Meter Functions
86
Keysight N8262A User’s Guide
Setting the Measurement Display
Using the gate settings, up to four measurements or a combination of
measurements can be shown on the display. Any of the 4 measurement display
lines can show any of the measurement results from any of the 4 gates, allowing
you complete control of the displayed information.
The power meter cannot display all 12 (or 24) measurements simultaneously.
Average, peak, and peak-to-average ratio are made within each gate period
generating possible measurement results per channel as shown in
Figure 2-43
Twelve measurements per channel
Gates 1 to 4
Peak
Average
Pk-to-Avg
Gate 1
Peak
Average
Pk-to-Avg
Feed 1
Feed 2
Feed 1
Feed 2
Feed 1
Feed 2
Feed 1
Feed 2
Gate 2
Gate 3
Gate 4
12
m
easu
re
men
ts
pe
r
ch
anne
l
Peak
Average
Pk-to-Avg
Peak
Average
Pk-to-Avg