107
Keysight InfiniiVision 2000 X-Series Oscilloscopes
User's Guide
7 Serial Decode
Serial Decode Options / 107
Lister / 108
Searching Lister Data / 110
Digital channels and serial decode cannot be on at the same time. The
[Serial]
key
takes precedence over the
[Digital]
key. Serial triggers can be used when digital
channels are on.
Triggering on
Serial Data
In some cases, such as when triggering on a slow serial signal (for example, I2C,
SPI, CAN, LIN, etc.) it may be necessary to switch from the Auto trigger mode to
the Normal trigger mode to prevent the oscilloscope from Auto-triggering and
stabilize the display. You can select the trigger mode by pressing the
[Mode/Coupling]
key, then the
Mode
softkey.
Also, the threshold voltage level must be set appropriately for each source
channel. The threshold level for each serial signal can be set in the Signals Menu.
Press the
[Serial]
key, then the
Signals
softkey.
Serial Decode Options
Keysight's hardware-accelerated serial decode options can be installed when the
oscilloscope is manufactured, or added later. The following serial decode licenses
are available:
• With the DSOX2AUTO license, you can decode CAN (Controller Area Network)
and LIN (Local Interconnect Network) serial buses. See:
•
•
Summary of Contents for DSO-X 2002A
Page 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 22: ...22 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 62: ...62 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 70: ...70 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 84: ...84 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms...
Page 106: ...106 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 112: ...112 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 146: ...146 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 154: ...154 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 180: ...180 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 216: ...216 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 228: ...228 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Page 246: ...246 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 266: ...266 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 20 Utility Settings...
Page 352: ...352 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide Index...