43
Betrieb / Operation / Provoz / Praca
5.6
Troubleshooting
Problem
Possible cause
Solution
The table
does not
move
The system is not plugged
in
The Actuator is not connec-
ted properly
Poor plug connection
The Actuator is defective
The hand switch is defec-
tive
Ensure that the system has been connected to
the Power Hub correctly
Ensure that the Actuator is properly connected
to all components of the system
Ensure that all plugs have been connected
properly
Contact Kesseböhmer
Contact Kesseböhmer
The table
only moves
slowly down-
wards
There was power failure
while the table was in
motion
The Power Hub was dis-
connected while the
device was in motion
Reset required
The Actuator is defective
Perform a Position Reset Procedure (see Chap-
ter 5.1 Performing a Position Reset Procedure)
Contact Kesseböhmer
The hand
switch does
not work
The hand switch is defec-
tive
Contact Kesseböhmer