Failure messages for the platform load control
In case the platform load control fails, open the door of the control panel and check if there
is one of the following failure messages in the display:
ER 10
Outside measuring range
Check the mechanical lever system for
being stuck.
ER 21
LO or HI values not correct
Contact
the
manufacturer
for
instructions
ER 22
Sensor overloaded
Replace the horizontal overload sensor
ER 23
HI value too high
Contact the manufacturer for instructions
ER 24
The load difference too small
Check the mechanical lever system for
being stuck.
ER 30
Failure in the control electronics
Replace the control electronics and
perform adjustment as instructed.
ER 70
Problem in wiring
Check wires and connections