Kesla
®
XS
190
SELF PROPELLED TELESCOPIC PLATFORM
45
MAINTENANCE
The Access Platform must be maintained regularly in order to keep it safe and efficient.
For descriptions of the necessary service procedures, refer to the maintenance scheme
and annual inspection list. If you feel uncertain about carrying out maintenance, do not
hesitate to contact a service shop specialized in Access Platforms for the maintenance
work and inspections needed.
PERIODIC MAINTENANCE
Carefully ensure cleanliness before opening hydraulic or fuel lines.
Change the engine oil after the first 50 hours of operation.
In normal conditions, change the oil again after 50 hours of operation; change also the oil
filter. In extremely dusty, hot or heavy environment or when the work load is exceptionally
high, the oil should be changed at intervals of 25 hours of operation. Use washing motor
oil, category SF. The required viscosity depends on the ambient temperature. Refer to the
table in the engine manual.
-
Change hydraulic oil and filter. The oil change intervals should be shortened in
dusty, humid or corroding environment, if the ambient temperature varies greatly, or if the
Access Platform is very heavily loaded.
MAINTENANCE SCHEME BASED ON OPERATING HOURS
Daily
1. Check fuel level
2. Check load-bearing structures
3. Check hydraulic hoses and pipes and tightness of hydraulic
couplings
4. Check the functioning of emergency stop and safety devices
5. Check all directions of functions. The functions should return
automatically to neutral positions.
Weekly
1. Check hydraulic oil level *
1. Lubricate all bearings and sliding surfaces
50h intervals
2. Check the condition of telescope sliding pads and surfaces,
lubricate and adjust as required
500h intervals
1. Change hydraulic oil and filter
2. Check how the boom movements can be stopped
1000h intervals or
at least every 6
months
1. Check the condition of driving brakes, clean, adjust and
lubricate
1. Annual inspection. Fill, sign and date the enclosed journal
form.
2. Check the tightness of the slewing gear fastening bolts **)
12 month intervals
3. Check the boom extension chains
The Access Platform in the transport position
*)
the Access Platform should in horizontal position, both lengthwise and crosswise
-
the oil level should be between Min and Max marks
**)
see instruction on page 60
Summary of Contents for XS 190
Page 1: ...190 SELF PROPELLED TELESCOPIC PLATFORM OPERATION MAINTENANCE ...
Page 6: ...Kesla XS 190 SELF PROPELLED TELESCOPIC PLATFORM 5 TRANSPORT DIMENSIONS ...
Page 8: ...Kesla XS 190 SELF PROPELLED TELESCOPIC PLATFORM 7 SPECIFICATION FRONT ...
Page 83: ...Kesla XS 190 SELF PROPELLED TELESCOPIC PLATFORM 82 ...