42
LOCATION OF THE SAFETY LIMIT SWITCHES AND THE
ELECTRIC COMPONENTS
The illustration above shows the location or the safety limit switches
1.
Outrigger limit switch, position limit switch, 4 switches
2.
Ground sensor limit switch, 4 switches
3.
Lifting radius limit switch, 2 switches
4.
Boom emergency limit switch, 1 switch
5.
Boom position limit switch, 1 switch
6.
Transport support limit switch, 1 switch
7
Jib limit switch, 1 switch
Location of other electric components:
8.
Electric junction box in the platform (emergency stop, emergency lowering switch,
main power switch, warning lamps for preheating and load control, the diesel engine fault
lamp
9.
Mains outlets, 2 outlets, 240VAC/16A
10. Ground fault interrupter
11. Electric junction box at the turntable (emergency stop, hour meter, emergency
lowering switch, main power switch, warning lamps for preheating, oil pressure, charging,
engine temperature, pressure filter, and return filter
12. Slip ring unit
13. Mains outlet 240VAC/16A
14
Pedal switch
15. Battery, on the left side (seen from the platform)