BHK-1/2-MG 030916
3-41
FIGURE 3-14. ANALOG PROGRAMMING OF OUTPUT CURRENT (CURRENT MODE) OR CURRENT
LIMIT (VOLTAGE MODE) USING GROUNDED LOW IMPEDANCE VOLTAGE SOURCE (VS)
3.8.3.1
VOLTAGE MODE
With the power supply in voltage mode (see Figure 3-11 or 3-12) and the digitally programmed
output voltage at zero, varying the low impedance voltage source from 0 to +10V causes the
output voltage of the power supply to vary linearly from 0 to E
O
max with a slope of (0.1 x
E
O
max) volts per volt. The following equations give the output voltage as determined by a low
impedance voltage source V
EXT
.