BHK-MG 1/2 (OPR) 030916
B-3
FIGURE B-1. PROGRAMMING THE OUTPUT
FIGURE B-2. USING DISPLAY COMMANDS
NOTES: 1. Power supply assumed to be operating in constant voltage mode.
2. Examples below are intended only to illustrate command functions. Refer to PAR. 3.6 for program-
ming techniques to optimize performance.
OUTP ON
Output enabled.
OUTP?
Power supply returns “1” (output enabled).
VOLT 221;CURR 1.5E-2
Power supply output programmed to go to 221V, current limit 15mA
INIT:CONT ON
Continuous triggers enabled.
INIT:CONT?
Power supply returns “1.”
VOLT:TRIG 215;CURR:TRIG 3E-2 Power supply output programmed to return to 215V, current limit 30mA
upon receipt of trigger.
*TRG
Power supply output returns to 215V,current limit 30mA.
VOLT 221;CURR 4E-2
Power supply output programmed to go to 221V, current limit 40mA
MEAS:VOLT?
If actual value of output voltage is 220.9V, power supply
returns 2.209E+2.
MEAS:CURR?
If actual value of output current is 0.0283A, power supply
returns 2.83E-2.
FUNC:MODE?
Returns VOLT if power supply operating in constant voltage
mode, CURR for constant current mode.
CURR:TRIG?
Returns 3E-2 (current value established by CURR:TRIG.
VOLT:TRIG?
Returns 215 (voltage value established by VOLT:TRIG.
ABOR
Pending trigger levels changed to 221V, 40mA (immediate values)
VOLT 277;CURR 2.5E-2
Power supply output programmed to go to 277V, 25mA
*TRG
Power supply output returns to 221V, current limit 40mA.
INIT:CONT 0
Triggers disabled.
INIT:CONT?
Power supply returns “0.”
OUTP OFF
Output disabled.
OUTP?
Returns 0 (output disabled).
MEAS:VOLT?
Returns 0. (measured output voltage).
VOLT?
Returns 221.(programmed output voltage)
CURR?
Returns 4E-2 (programmed current 40mA)
CURR? MAX
Returns 4E-2 (assuming maximum allowable current for power
supply being addressed is 40mA, i.e. BHK 1000-40MG).
CURR? MIN
Returns 0 (minimum allowable current).
CURR:PROT 3.8E-2
Current protection set to 38mA.
CURR?
Returns 4E-2 (programmed current 40mA)
CURR:PROT?
Returns 3.8E-2 , indicating programmed overcurrent protection
current value = 38mA.
CURR:PROT? MAX
For BHK 1000-40MG, returns 4.4E-2 (44mA, see Table 1-2).
SYST:VERS?
Returns 2003.0.
DISP:CONT 0.9
Sets LCD contrast value to 0.9.
DISP:CONT?
Returns 0.9.
DISP:MODE NORM
Changes LCD to Normal metering mode.
DISP:MODE?
Returns NORMAL.
DISP:MODE TEXT
Changes LCD to Text mode.
DISP:TEXT “**BHK IS IN USE”
Second line of display reads **BHK IS IN USE.
DISP:MODE?
Returns “TEXT”.
DISP:TEXT?
Returns “**BHK IS IN USE”.
Summary of Contents for BHK-MG Series
Page 2: ......
Page 6: ......
Page 16: ......
Page 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Page 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Page 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Page 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Page 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Page 150: ......