BHK-MG 1/2 (OPR) 030916
B-5
B.13
INITiate:CONTinuous? QUERY
INIT:CONT?
Syntax
:
Short Form: INIT:CONT?
Long Form: INITiate:CONTinuous?
Return Value: 1 or 0
Description:
Determines whether continuous triggers are enabled or disabled.
Power supply returns value of
INIT:CONT flag: “1” = continuous triggers are enabled (INIT:CONT ON); “0” = continuous triggers dis-
abled (INIT:CONT OFF). (See example, Figure B-1.)
B.14
INSTrument:STATe COMMAND
INST:STAT
Syntax
:
Short Form: INST:STAT <boolean>
Long Form: INSTrument:STATe <boolean>
<boolean>=(0 or OFF, 1 or ON)
Description: Operation is identical to OUTPut:STATe command (PAR. B.36) and is provided for compatibility with
other vendors products.
B.15
INSTrument:STATe? QUERY
INST:STAT?
Syntax
:
Short Form: INST:STAT?
Long Form: INSTrument:STATe <val>
Description: Operation is identical to OUTPut:STATe? query (PAR. B.37) and is provided for compatibility with other
vendors products.
B.16
[SOURce:]LIST:CLEar COMMAND
LIST:CLE
Syntax:
Short Form: LIST:CLE
Long Form: LIST:CLEar>
Description:
Clears all list entries by setting all pointers to 0.
Also sets LIST:DIR to UP, LIST:COUN 1. Related
Commands: All LIST commands (See example, Figure B-3.)
B.17
[SOURce:]LIST:COUNt COMMAND
LIST:COUN
Syntax:
Short Form: LIST:COUN<int_value 0 to 65535> Long Form: LIST:COUNt> <int_value 0 to 65535>
Description:
Establishes how many times the list is executed.
Allows user to establish how many times the list
is executed. The order (beginning to end or end to beginning) is determined by LIST:DIR. For
LIST:COUN 0, the unit will execute the sequence indefinitely until a VOLT:MODE FIXED command is
received. Related Commands: LIST:DIR. (See example, Figure B-3.)
B.18
[SOURce:]LIST:COUNt? QUERY
LIST:COUN?
Syntax:
Short Form: LIST:COUNT?
Long Form: LIST:COUNt?
Return Value: <int_value>
Description:
Identifies how many times the list will be executed.
Returns value set by LIST:COUN command.
(See example, Figure B-3.)
B.19
[SOURce:]LIST:COUNt:SKIP COMMAND
LIST:COUN:SKIP
Syntax:
Short Form: LIST:COUN:SKIP nn
Long Form: LIST:COUNt:SKIP nn
nn = <int_value 0 to 65535>
Description:
Allows beginning steps of list-generated waveform to be run once, then ignored.
When a list is to be repeated using LIST:COUNT, this command allows the user to skip the first nn
steps once the full set has been executed. After the first iteration (which executes all steps), the first
nn steps are skipped. The LIST:COUN:SKIP command allows the user to precondition a list-generated
waveform by setting unique conditions at the beginning that are not repeated for the rest of the repeti-
tions. LIST:CLEar sets nn to 0. Only works in LIST:DIR UP mode, if LIST:DIR DOWN is issued, this
command has no effect. Related Commands: LIST:COUN, LIST:COUN:SKIP?, LIST:DIR, LIST:CLE.
(See example, Figure B-3.)
Summary of Contents for BHK-MG Series
Page 2: ......
Page 6: ......
Page 16: ......
Page 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Page 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Page 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Page 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Page 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Page 150: ......