B-6
BHK-MG 1/2 (OPR) 030916
B.20
[SOURce:]LIST:COUNt:SKIP? QUERY
LIST:COUN:SKIP?
Syntax:
Short Form: LIST:COUN:SKIP? Long
Form:
LIST:COUNt:SKIP?
Return Value: <int_value>
Description:
Identifies how many steps will skipped the first time the list is executed.
Returns value set by
LIST:COUN:SKIP command. (See example, Figure B-3.)
B.21
[SOURce:]LIST:CURRent COMMAND
LIST:CURR
Syntax:
Short Form: LIST:CURR <exp_value>, <exp_value>, . . . (to max of 250 data points)
Long Form: LIST:CURRent <exp_value>, <exp_value>, . . . (to max of 250 data points)
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1
Description:
Adds the current value (in Amps) to list.
This command sequentially adds LIST:CURRent values to
the main channel List Data Table. Starting location is indicated by LIST:CURR:POIN? The maximum
number of entries is 250. Since the input buffer of the BHK has a limit of 253 characters, multiple com-
mands are necessary to complete the full 250 entries of the list. If LIST:CURR is entered only for loca-
tion 0, that current will apply to all steps when VOLT:MODE LIST is executed. Related Commands:
LIST:CURR:POIN?. (See example, Figure B-3.)
B.22
[SOURce:]LIST:CURRent? QUERY
LIST:CURR?
Syntax:
Short Form: LIST:CURR?
Long Form: LIST:CURRent?
Return Value: <value1>, <value2>, . . . to <value16>
Description:
Identifies the parameters (main channel) entered for the list.
Starting at location established by
LIST:QUERy, returns comma-separated list of up to 16 values indicating the main channel parameters
entered. i.e., the contents of main channel List Data Table. Related Commands: LIST: CURR,
LIST:QUERy. (See example, Figure B-3.)
B.23
[SOURce:]LIST:CURRent:POINts? QUERY
LIST:CURR:POIN?
Syntax:
Short Form: LIST:CURR:POIN? Long
Form:
LIST:CURRent:POINts?
Return Value: <value> (0 to 250)
Description:
Identifies the total number of points in a list and the next location to be filled by LIST:CURR
command.
The LIST:CURR pointer is initially at 0 via LIST:CLE. For each data point entered by a
LIST:CURR command the list pointer is incremented If LIST:CURR:POIN? returns 5, the LIST:CURR
pointer is at 5 indicating there are 6 data points comprising the list. Related Commands: LIST:CURR.
(See example, Figure B-3.)
B.24
[SOURce:]LIST:DIRection COMMAND
LIST:DIR
Syntax:
Short Form: LIST:DIR (UP|DOWN)
Long Form: LIST:DIRection (UP|DOWN)
Description:
Allows the list to be executed from beginning to end (UP) or from end to the beginning
(DOWN).
LIST:CLEar sets the list to the UP direction (beginning to end)
.
Related Commands:
LIST:DWEL?. (See LIST example, Figure B-3.)
B.25
[SOURce:]LIST:DIRection? QUERY
LIST:DIR?
Syntax:
Short Form: LIST:DIR?
Long Form: LIST:DIRection?
Return Value: <value> (1 or 0)
Description:
Identifies the direction (1 = up or 0 = down) for executing the list established by LIST:DIR.
Related Commands: LIST: DIR. (See example, Figure B-3.)
B.26
[SOURce:]LIST:DWELl COMMAND
LIST:DWEL
Syntax:
Short Form: LIST:DWEL <value> (0.010 to 655.35),<value>,<value>, . . . to maximum of 250 values
Long Form: LIST:DWELl <value> (0.010 to 655.35),<value>,<value>, . . . to maximum of 250 values
Description:
Determines how long the main channel parameters will be active.
Sets time value (from 0.010 to
655.35) in seconds for List:Dwell locations of the List Data Table. The main channel (either voltage or
current) is determined by the load. If LIST:DWEL is entered for only location 0, that time duration will
apply to all steps when either VOLT:MODE LIST or CURR:MODE LIST is executed. Related Com-
mands: VOLT:MODE, LIST:CURR, LIST:VOLT, LIST:DWEL? (See example, Figure B-3.)
Summary of Contents for BHK-MG Series
Page 2: ......
Page 6: ......
Page 16: ......
Page 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Page 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Page 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Page 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Page 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Page 150: ......