BHK-MG 1/2 (OPR) 030916
B-17
B.69
SYSTem:COMMunication:GPIB:ADDRess
COMMAND
SYST:COMM:GPIB:ADDR
Syntax
:
Short Form: SYST:COMM:GPIB:ADDR<INT VAL> 1 to 30
Long Form: SYSTem:COMMunication:GPIB:ADDRess<INT VAL> 1 to 30
Description:
Sets selected power supply GPIB address.
(See PAR. 3.3.5.2 and Figure 3-2 for special program-
ming considerations.)
B.70
SYSTem:COMMunication:GPIB:ADDRess? QUERY
SYST:COMM:GPIB:ADDR?
Syntax
:
Short Form: SYST:COMM:GPIB:ADDR?
Long Form: SYSTem:COMMunication:GPIB:ADDRess?
Return Value: <int_value> 1 to 31
Description:
Returns selected power supply GPIB address.
B.71
SYSTem:COMMunication:SERial:BAUD COMMAND
SYST:COMM:SER:BAUD
Syntax
:
Short Form: SYST:COMM:SER:BAUD {19200 | 9600 | 4800 | 2400}
Long Form: SYSTem:COMMunication:SERial:BAUD {19200 | 9600 | 4800 | 2400}
Description:
Sets the unit to operate at the specified baud rate.
(See PAR. 3.3.5.2 and Figure 3-2 for special
programming considerations.)
B.72
SYSTem:COMMunication:SERial:BAUD? QUERY
SYST:COMM:SER:BAUD?
Syntax
:
Short Form: SYST:COMM:SER:BAUD?
Long Form: SYSTem:COMMunication:SERial:BAUD?
Return Value: <int_value> {19200 | 9600 | 4800 | 2400}
Description:
Returns operating baud rate.
B.73
SYSTem:COMMunication:SERial:ECHO
COMMAND
SYST:COMM:SER:ECHO
Syntax
:
Short Form: SYST:COMM:SER:ECHO {ON | OFF} or {01 | 00}
Long Form: SYSTem:COMMunication:SERial:ECHO {ON | OFF} or {01 | 00}
Description:
Enables (ON or 01) or disables (OFF or 00) echo mode
(see PAR. 3.5.3.1) Sending ON or 01
causes all subsequent characters to be echoed back. Sending OFF or 00 turns off the character echo
after the next line terminator character. The *RST command has no effect on echo status. (See PAR.
3.3.5.2 and Figure 3-2 for special programming considerations.)
B.74
SYSTem:COMMunication:SERial:ECHO? QUERY
SYST:COMM:SER:ECHO?
Syntax
:
Short Form: SYST:COMM:SER:ECHO?
Long Form: SYSTem:COMMunication:SERial:ECHO?
Return Value: {01 | 00}
Description:
Returns 01 when echo mode is active (ON) or 00 when disabled (OFF)
(see PAR. 3.5.3.1).
B.75
SYSTem:COMMunication:SERial:PACE COMMAND
SYST:COMM:SER:PACE
Syntax
:
Short Form: SYST:COMM:SER:PACE {NONE | XON}
Long Form: SYSTem:COMMunication:SERial:PACE {NONE | XON}
Description:
Enables (XON) or disables (NONE) data flow control via the serial interface.
(See PAR. 3.5.3.3).
(See PAR. 3.3.5.2 and Figure 3-2 for special programming considerations.)
B.76
SYSTem:COMMunication:SERial:PACE? QUERY
SYST:COMM:SER:PACE?
Syntax
:
Short Form: SYST:COMM:SER:PACE?
Long Form: SYSTem:COMMunication:SERial:PACE?
Return Value: {01 | 00}
Description:
Returns 01 when data flow control via the serial interface is enabled (XON) or 00 when disabled
(NONE)
(see PAR. 3.5.3.3).
Summary of Contents for BHK-MG Series
Page 2: ......
Page 6: ......
Page 16: ......
Page 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Page 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Page 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Page 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Page 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Page 150: ......