25
SUPERtrol-I LE Flow Computer
6.4.9
SETUP RELAYS
(Relay 1 & Relay 2)
Select the desired Relay for setup.
(Relays 3 & 4 Optional, menus will always appear even if
option not installed)
If Relay 1 or Relay 2 Selected,
Select Rate, Total or NA.
If Rate selected, enter desired relay activation delay
value. Alarm condition must be continuously present for
this amount of time before alarm will activate.
If Total Selected, Enter desired Relay Duration.
Select the desired Relay Activation.
Low: Relay activates when reading is below setpoint.
High: Relay activates when reading is above setpoint.
Enter the desired Setpoint. The Setpoint can be edited in
run mode using the PRE 1 key (PRE 2 key for Relay 2).
If Rate, selected, Enter desired Relay Hysteresis.
NOTE:
In Batch mode,
Relay 1 is reserved
for Preset,
Relay 2 is reserved
for Prewarn or NA
(not assigned).
SETUP RELAYS
Rly1
Rly2
Rly3 Rly4
RELAY 1 USAGE
RATE TOTAL NA
RELAY 1 DELAY sec
0
RELAY 1 DURATION
#####
RELAY 1 MODE
LO_ALARM HI_ALARM
RELAY 1 SETPOINT
####### gal
RELAY 1 HYSTERESIS
##### gal/m
Advance To
SETUP RELAYS 3, 4
Notes
Display
Sub-menus