4 NXDN function
98
Scan Function (
Dwell Time
)
Type
‘
■
Standard model
■
Basic model
Description
During the scan, the scan pauses when the
PTT
switch is pressed to transmit.
Dwell Time
is the time from when
the transceiver completes transmitting until the transceiver resumes scanning.
The transceiver activates Talkback according to the configuration in
Revert Channel
while the time configured
in
Dwell Time
elapses.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Dwell Time
: Edit > Scan Information > Scan
Scan Function (
Power-on Scan
)
Type
‘
■
Standard model
■
Basic model
Description
Power-on Scan
is the function to start the scan automatically when the transceiver is turned on.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Power-on Scan
: Edit > Scan Information > Scan
Scan Function (
Revert Channel
)
Type
‘
■
Standard model
■
Basic model
Description
Revert Channel is the Zone-channel which is used when the transceiver transmits by pressing the
PTT
switch
during the scan.
The Revert Channel is displayed according to the configuration of Revert Channel Display.
Priority
Configuration
Description
Last Selected
The transceiver transmits on the last-called Zone-channel by pressing the
PTT
switch during the scan.
If the Zone-channel is changed, the transceiver transmits using the new channel
after the Zone channel is changed until the transceiver receives another call.
Selected
The transceiver transmits on the new channel after the Zone-channel is changed
regardless of the scan status.
Se Talkback
During the scan, the transceiver transmits on the new Zone-channel after the
zone-channel is changed.
While the scan is paused, the transceiver transmits on the Zone-channel where
the transceiver pauses scanning.
Priority 1
The transceiver transmits on a Priority 1 regardless of the scanning status.
Priority 1 + Talkback
The transceiver transmits on a Priority 1 during the scan.
While the scan is paused, the transceiver transmits on the Zone-channel where
the transceiver pauses scanning.
Priority 2
The transceiver transmits on a Priority 2 regardless of the scanning status.
Priority 2 + Talkback
The transceiver transmits on a Priority 2 during the scan.
While the scan is paused, the transceiver transmits on the Zone-channel where
the transceiver pauses scanning.
Operating the transceiver
-
-
Note
If
Revert Channel Display
is enabled, a Revert Channel always appears on the transceiver display during the
scan.
Configuration using FPU
Revert Channel
: Edit > Scan Information > Scan