3 DMR function
45
Automatically Transmitting and Receiving in Emergency Mode (
Receive Duration
)
Type
‘
■
Standard model
■
Basic model
Description
Receive Duration
is the duration for a single session of automatic reception for emergency in Emergency
Mode.
The transceiver switches to automatic transmission for emergency when the time configured in
Receive
Duration
elapses after the transceiver starts automatic reception for emergency.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Receive Duration
: Edit > Emergency Information > Profiles > Page 2 > Option
Automatically Transmitting and Receiving in Emergency Mode (
Transmit Duration
)
Type
‘
■
Standard model
■
Basic model
Description
Transmit Duration
is the duration of a single automatic transmission cycle in Emergency Mode.
The transceiver switches to automatic reception for emergency when the time configured in Transmit Duration
elapses after the transceiver starts automatic transmission for emergency.
The transceiver behaves as follows when “0” is configured in
Transmit Duration
:
If
“
None
”
is configured for Emergency ID:
The transceiver does not send anything during automatic transmission.
If anything other than
“
None
”
is configured for Emergency ID:
The transceiver sends only an Emergency Status during automatic transmission.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Transmit Duration
: Edit > Emergency Information > Profiles > Page 2 > Option
Indication and Sound in Emergency Mode (
Remain Surveillance Mode
)
Type
‘
■
Standard model
□
Basic model
Description
Remain Surveillance Mode
is the function to continue the Surveillance function as enabled even if the
transceiver enters Emergency Mode while the Surveillance function is enabled.
While the Surveillance function is enabled, the transceiver does not emit a tone or light the backlight even when
the transceiver functions.
The Surveillance function is used when the change of the transceiver status needs to be kept unnoticed, such as
while on a Public Safety operation.
The transceiver behaves as follows according to the configuration in
Remain Surveillance Mode
.
If Remain Surveillance Mode is enabled
Even if the transceiver enters Emergency Mode while the Surveillance function is enabled, the Surveillance
function remains enabled, and the transceiver does not emit a tone and the backlight and LED do not light.
The Surveillance function remains enabled even if the transceiver exits Emergency Mode.
If Remain Surveillance Mode is disabled
The Surveillance function is disabled if the transceiver enters Emergency Mode while the Surveillance function
is enabled.
The transceiver behaves according to the configurations in Emergency Mode when the transceiver is placed in
Emergency Mode. The Surveillance function remains disabled even if the transceiver exits Emergency Mode.
Operating the transceiver
-
-
Note
While in Emergency Mode, the Surveillance function cannot be toggled between enabled and disabled by
operating the transceiver.
Configuration using FPU
Remain Surveillance Mode
: Edit > Emergency Information > General