4 NXDN function
62
Configuring the Alert Tone Pattern (
Special Alert Tone
)
Type
‘
■
Standard model
■
Basic model
Description
This tone sounds from the transceiver when the transceiver receives various types of calls, Status Message, or
Short Message. A maximum of 8 types of tones can be arbitrarily configured or changed.
An Alert Tone sounds from the transceiver such as when the transceiver receives a call using an Individual Call
or a Group Call, a Status Message, or a Short Message and notifies the user of the reception.
The Alert Tone pattern can be configured by selecting from 8 types of tones configured in
Special Alert Tone
.
Alert Tone is the alert tone pattern when receiving a call with the optional signaling.
An Alert Tone that is suitable for a user
’s environment can be selected.
Alert Tone can be used to select from 8 patterns of Alert Tones. An Alert Tone pattern consists of 16 tones.
Alert Tone can be configured by using KPG-D6/ D6N.
The following table shows the configuration items.
Alert Tone
Configuration
Description
Cycle
This function can be used to configure the number of times for the Alert Tone that
sounds from the transceiver. A number from 1 to 255 can be configured.
The Alert Tone sounds from the transceiver until it is manually stopped if
“
Infinite
”
is configured.
If it is intended for the Alert Tone to sound multiple times, the Alert Tone does not
sound from the transceiver while the transceiver unmutes the speaker. Or, if the
matching state of Optional Signaling is reset, Alert Tone will also be disabled.
Interval Time
This function can be used to configure the timing to repeat the Alert Tone that
sounds from the transceiver.
A time between 0 s and 255 s can be configured in steps of 1 s.
Frequency
The tone frequency can be configured.
A frequency between 400 Hz and 2500 Hz can be configured in steps of 10 Hz.
Gap can be configured if
“
None
”
is selected.
Length
The tone length can be configured.
A tone length between 0 ms and 2500 ms can be configured in steps of 10 ms.
No tone sounds if 0 ms is configured.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Cycle
,
Interval Time
,
Frequency
,
Length
:
Edit > Special Alert Tone
Restricting an Alert Tone When Consecutively Receiving a Call (
Alert Tone Inhibit from 2nd Call
)
Type
‘
■
Standard model
■
Basic model
Description
Alert Tone Inhibit from 2nd Call
is the function that disables the functions such as the storing of a Caller ID in
the transceiver stack memory and the activation of various alerts, if the transceiver consecutively receives an
Individual Call from the transceiver having the same Individual ID, or receives a Group Call with the same Group
ID after the transceiver receives an Individual Call or a Group Call.
For instance, emitting an Alert Tone from the transceiver every time the transceiver repeatedly and frequently
receives a call from the same party may be annoying. In that case, this function can be used to disable the Alert
Tone for sounding from the transceiver even if the transceiver receives a call from the same party in succession.
Operating the transceiver
-
-
Note
If
Alert Tone Inhibit from 2nd Call
is enabled, various functions such as Alert Tone will not be activated upon
the
reception of the second and subsequent calls from the same transceiver even if “Off” is configured in
Auto
Reset Timer
.
If “0” configured in
Auto Reset Time
r,
Alert Tone Inhibit from 2nd Call
will not be activated.
Configuration using FPU
Alert Tone Inhibit from 2nd Call
: Edit > NXDN > General 1
Auto Reset Timer
,
LCD
,
LED
,
Alert Tone
:
Edit > NXDN > General 2 > Auto Reset > Voice
Auto Reset Timer
,
LCD
,
Alert Tone
:
Edit > NXDN > General 2 > Auto Reset > Message