- 70 -
7-7. Damper
Function
The damper supplies the cold air at freezer room to chillroom
by using the damper s plate. Chillroom is colder than before
when damper s plate is open. When damper’s plate is close,
chillroom s temperature will rise.
How to
Measure
< Damper Circuit >
< extension >
Check the ,
Standard
Damper
Test Points
Red and Yellow
Result
373 ~ 456
Ω
Test Points
Blue and White
Result
373 ~ 456
Ω
Check the resistance between connectors 1, 3 and 2, 4.It means
check whether or not applying an electric current. If there is
resistance, it means the damper not inferiority
1
Blue
1
Blue
2
Red
3
White
3
White
1
3
Check the ,
2
4
Check the ,
3
1
3
Yellow