- 45 -
Icing Room Fan Error
Is Er-IF displayed?
Is the connection loose?
Reconnect
Is the feedback voltage
between pin6 and pin7 of
CON4 like as below?
(from motor to main board)
Does the cold-air come out
of the side duct under the
Test1 Mode?
Check fan motor
(Connector,
Frozen, Locked)
and replace.
(Position
No : 407A)
No
Replace
MAIN PWB
(Position No:
500A)
No
Yes
Yes
Yes
Yes
Feedback Voltages
Test Point
Pin6 To Pin7
Result
1 ~ 4 V
Icing Fan Voltages
Test Point
Pin5 To Pin6
Result
10 ~ 16 V
Yes
No
Reset and
Enter the TEST 1 MODE
Is the output voltage
between pin5 and pin6 of
CON4 like as below?
Replace
MAIN PWB
(Position
No: 500A)
Explain to the customer!
No
Pin5 RD
Pin6 BL
Pin6 BL
Pin7 BN